Fig. 3 | Journal for ImmunoTherapy of Cancer

Fig. 3

From: Characterization of a whole blood assay for quantifying myeloid-derived suppressor cells

Fig. 3

Collection tube type affects MDSC quantitation. Blood samples were simultaneously collected in Na+ heparin and K2EDTA tubes and tested using the WB assay. Representative plots of total and M-MDSC populations for samples collected from the same subject in the two tube types are shown (a). Quantitative results for the total and M-MDSC populations (cells/μL) from 5 unique individuals, 2 healthy and 3 with HCC, are shown (b). Mean percent differences between K2EDTA and Na+ heparin tubes for total MDSC and M-MDSC cell counts were 63% and 73%, respectively. P-values were obtained using paired t tests